96 Nucleic Acid Extraction Workstation samples for DNA and RNA extraction
- $8690.00 / 1 - 4 units
$7510.00 / >=5 units - 1 unit
- Guangzhou Four E's Scientific Co., Ltd.
- Guangdong, China
- Ms Susan Zhou
PRODUCT DETAIL
product name: | Nucleic acid extractor | payment terms: | Western Union, T/T, PayPal |
After-sales service: | free spare parts | brand: | Four E's |
safety standard: | not any | model: | RV131 |
Material: | Metal plastic | Number of samples: | 1-96 |
Volume capacity: | 50-1000μL | Number of plates: | 6 |
Origin: | Guangdong, China | Warranty: | 2 years |
Processing time: | 20 min - 40 min/run (depending on reagent type and volume) | Reagent type: | Magnetic Bead-Based Open Source Reagents |
Shelf life: | 2 years | Model: | Multiple EX 096 |
Instrument classification: | Level three | port: | Guangzhou |
Energy source: | mechanical | Plate type: | 96-well deep well plate |
Supply capacity: | 1000 units per month | Packaging Details: | export carton |
Quality Certification: | CE | Program Management: | Available create, edit and delete options |
Product Description
Nucleic Acid Extraction - MultiEX 096
The MultiEX family of products provides automated nucleic acid extraction and purification using magnetic bead separation. The MultiEX 032 system can process up to 32 samples per run to meet your common nucleic acid extraction needs. The MultiEX 096 is a high-throughput system that can process up to
96 samples per run. The MultiEX series extractor adopts magnetic bead separation technology, which can extract and purify nucleic acid from various biological samples such as whole blood, viruses, tissues, plants, animals, fungi, bacteria, cultured cells, swabs, feces, and blood. The system is equipped with a user-friendly touch screen interface that allows users to easily set purification parameters. This automated system integrates all purification stages including binding, mixing, washing and elution and provides efficient, high-quality purification. The system can be used with any prefilled magnetic bead kit.
96 samples per run. The MultiEX series extractor adopts magnetic bead separation technology, which can extract and purify nucleic acid from various biological samples such as whole blood, viruses, tissues, plants, animals, fungi, bacteria, cultured cells, swabs, feces, and blood. The system is equipped with a user-friendly touch screen interface that allows users to easily set purification parameters. This automated system integrates all purification stages including binding, mixing, washing and elution and provides efficient, high-quality purification. The system can be used with any prefilled magnetic bead kit.
feature
* Stable and efficient
Automated processing avoids discrepancies and errors caused by manual operations and improves efficiency.
* Easy to use
The 10-inch color touch screen and user-friendly interface allow you to easily set purification parameters.
* Pollution Control
Built-in UV disinfection lamp to eliminate cross-contamination.
* Advanced mixing technology
The stirring speed is as high as 10HZ (up and down 10 times in 1 second), which can effectively mix high-viscosity substances (blood, feces, etc.).
* Multiple heating modules
A heating block with individual heating controls ensures high precision in lysis and elution.
* Safe and reliable
After the safety door is opened, the operation is automatically suspended, and the operation is resumed after the safety door is closed, providing better protection for users.
* Self-diagnosis
Automatic checks before each run ensure that sockets, rods and orifice plates are positioned correctly, avoiding any errors due to omissions or interference.
* Stable and efficient
Automated processing avoids discrepancies and errors caused by manual operations and improves efficiency.
* Easy to use
The 10-inch color touch screen and user-friendly interface allow you to easily set purification parameters.
* Pollution Control
Built-in UV disinfection lamp to eliminate cross-contamination.
* Advanced mixing technology
The stirring speed is as high as 10HZ (up and down 10 times in 1 second), which can effectively mix high-viscosity substances (blood, feces, etc.).
* Multiple heating modules
A heating block with individual heating controls ensures high precision in lysis and elution.
* Safe and reliable
After the safety door is opened, the operation is automatically suspended, and the operation is resumed after the safety door is closed, providing better protection for users.
* Self-diagnosis
Automatic checks before each run ensure that sockets, rods and orifice plates are positioned correctly, avoiding any errors due to omissions or interference.
Specification
thing | value |
birthplace | China |
Guangdong | |
brand | Four E's |
model | Multiple EX 096 |
energy source | mechanical |
Warranty | 2 years |
After-sales service | free spare parts |
Material | Metal plastic |
shelf life | 2 years |
Quality Certification | CE |
Instrument classification | Class I |
safety standard | not any |
product name | Nucleic acid extractor |
Model | Multiple EX 096 |
volume capacity | 50-1000μL |
Number of samples | 1-96 |
Plate quantity | 6 |
plate type | 96-well deep well plate |
processing time | 20 min - 40 min/run (depending on reagent type and volume) |
Reagent type | Magnetic Bead-Based Open Source Reagents |
program management | Available create, edit and delete options |
heating temperature | Room temperature~125℃ |
VIEW MORE