Factory direct sale of spare parts for home appliances, 1000W magnetron microwave oven
- $20.00 / >=2 pieces
- 2 pieces
- Zhuhai Pindom Technology Co., Ltd.
- Guangdong, China
- Ms Kitty Zhong
PRODUCT DETAIL
Cooling Type: | Domestic commercial microwave oven | model: | OM75P-11-ESDYF |
quality: | Excellent | frequency: | 2465MHz |
Energy source: | Batteries, Electricity, Vehicle Power | Packaging Details: | Industrial microwave custom equipment is packed in iron hoop wooden boxes. |
Watts: | 1000W | After-sales service provided: | not any |
port: | Shenzhen, China | place of origin; place of origin: | Guangdong, China |
product name: | magnetron | type: | Microwave Accessories |
brand: | market | strength: | 1000W Magnetron |
cooling method: | air cooling | payment terms: | L/C,Western Union,D/P,D/A,T/T |
Supply capacity: | 500 pieces per month | heat sink: | 6 pieces |
Material: | aluminum | application: | Outdoor, Hotel, Commercial, Home |
The original: | Ningguo China | Warranty: | 1 year |
Specification
thing | Factory direct sales of home appliance spare parts microwave oven 1000W magnetron |
Model | OM75P-11-ESDYF |
cool down | air cooling |
Voltage | 4.5kv |
Storage temperature | -35°C to +60°C |
RF coupler | WR430 system |
Cooling water flow | 1.40 L/min |
microwave frequency | 2465HMz |
Output Power | 1000W |
Product Description
2465MHz 1.0kW
Water-cooled magnetron
The OM75P is a continuous wave magnetron with a fixed frequency of 2465MHz and high efficiency.
For the power supply, an LC single-phase half-wave frequency multiplier should be used.
- Filament voltage should be measured at the tube terminals.
- The combination of transformer and capacitor should be chosen such that for normal line voltage, Ia mean =330mA±1% and la peak 1020 to 1050mA.
- It is recommended to use 10-12KV avalanche diodes as protection for capacitors and transformers.
- See pages 5 and 6 for waveguide configuration and power supply.
- A water load of VSWR≤1.1 in the 2425MHz to 2475MHz frequency band should be used.
- Unless otherwise stated, restrictions apply to tubes within 15 seconds after voltage is applied and at 25°C.
- Tubes should be "at room temperature" for at least four hours prior to testing.
- During the test, the magnetron shall be forced water cooled at 1.40L/min in.
- Filament voltage should be measured at the tube terminals.
- The combination of transformer and capacitor should be chosen such that for normal line voltage, Ia mean =330mA±1% and la peak 1020 to 1050mA.
- It is recommended to use 10-12KV avalanche diodes as protection for capacitors and transformers.
- See pages 5 and 6 for waveguide configuration and power supply.
- A water load of VSWR≤1.1 in the 2425MHz to 2475MHz frequency band should be used.
- Unless otherwise stated, restrictions apply to tubes within 15 seconds after voltage is applied and at 25°C.
- Tubes should be "at room temperature" for at least four hours prior to testing.
- During the test, the magnetron shall be forced water cooled at 1.40L/min in.