Scanning UV/Vis Spectrophotometer with GLP Self Test UV-Vis Spectrophotometer Price
- $79.00 / 1 - 49 sets
$75.00 / >=50 sets - 1 set
- Guangzhou Max Laboratory Equipment Co., Ltd.
- Guangdong, China
- Ms Ada Liu
PRODUCT DETAIL
Optical system: | double beam | Wavelength Accuracy: | 3 Nm |
Packaging Preview: | weight: | 1.7kg | |
payment terms: | L/C,Western Union,T/T,MoneyGram | place of origin; place of origin: | China |
exhibit: | 7 inch LCD screen | light source: | Tungsten filament lamp |
application: | Standard Configuration Mode Analysis Scope | Packaging Details: | Plywood 1. Inner thick paper 2. Outer double bubble film 3.7 to 18mm plywood 4. PET tape to prevent damage |
Stray light: | 0.3% | port: | Guangzhou/Shenzhen |
Supply capacity: | 600 sets per month | detector: | BOOST Si-PIN Detector |
Spectral Bandwidth: | auto switch | product name: | Spectrophotometer |
1. Metering
Absolute value, transmittance and energy testing with fixed wavelength
2. Quantitative
Two modes of linear fitting and zero-crossing linear fitting
a. Three modes of coefficient, standard sample input and standard sample read to establish a standard curve
b. Establish A=K1*C+K0, can search original data, graph curve, parameter setting
C. Can save 240 sets of curves, each curve can test 240 data
d. Dual-wavelength, three-wavelength test function
3. Dynamics
For time history scans or reaction rate calculations of A/t, all data can be searched.
4. Multi-wavelength
Transmittance and absolute values can be tested. Up to 8 different wavelengths
5. Scan
The user can set the scan range from 190nm to 1100nm to test the maximum. absolute value. Peak, you can do derivation and arithmetic operations on the graph.
6. Biology
6 methods: DNA/Protein, UV, Lowry, BCA, CBB and Biuret
Absolute value, transmittance and energy testing with fixed wavelength
2. Quantitative
Two modes of linear fitting and zero-crossing linear fitting
a. Three modes of coefficient, standard sample input and standard sample read to establish a standard curve
b. Establish A=K1*C+K0, can search original data, graph curve, parameter setting
C. Can save 240 sets of curves, each curve can test 240 data
d. Dual-wavelength, three-wavelength test function
3. Dynamics
For time history scans or reaction rate calculations of A/t, all data can be searched.
4. Multi-wavelength
Transmittance and absolute values can be tested. Up to 8 different wavelengths
5. Scan
The user can set the scan range from 190nm to 1100nm to test the maximum. absolute value. Peak, you can do derivation and arithmetic operations on the graph.
6. Biology
6 methods: DNA/Protein, UV, Lowry, BCA, CBB and Biuret
feature:
Adopt advanced grating, fully sealed optical path design to ensure the instrument has ultra-low stray light
Advanced system monitors the lifetime of deuterium and tungsten lamps in real time
With GLP self-check function, check wavelength accuracy and photometric accuracy
Wavelength calibration, wavelength setting, automatic lamp replacement and dark current calibration
Adopt SiO2 coated optical mirror to fully reduce external pollution
Advanced system monitors the lifetime of deuterium and tungsten lamps in real time
With GLP self-check function, check wavelength accuracy and photometric accuracy
Wavelength calibration, wavelength setting, automatic lamp replacement and dark current calibration
Adopt SiO2 coated optical mirror to fully reduce external pollution
VIEW MORE