Place of origin: | Guangdong, China | Battery output fuse: | 10A/250V 5*20mm glass tube fuse slow blow |
thing: | Addressable fire alarm control panel | brand: | asenwa |
spare battery: | Two 12V/7Ah lead-acid batteries connected in series | model: | AW-FP200 |
AC power input fuse: | 3.15A/250V 5*20mm glass tube slow-blow fuse | payment terms: | Letter of credit, wire transfer |
size: | 424*501*127mm | Maximum load current per circuit: | 24VDC 1A (maximum) |
port: | Zhongshan | Rated input voltage: | 85-260VAC 50Hz/60Hz |
Fault output: | Normal output is 24VDC/200mA (Max), fault output is -12VDC | Auxiliary power: | Resettable 24VDC 200mA (maximum) |
FA output: | Normal output -12VDC Fire alarm output 24VDC/200mA (maximum) | Packaging details: | Double corrugated box surrounded by polystyrene foam exterior |
Supply capacity: | 100,000 sets per month |
Product Description
The AW-FP200 series addressable fire alarm controller adopts a 7-inch LCD touch screen, button operation, easy operation, and beautiful human-machine interface. This machine can connect 8 loops. Each loop can connect 250 devices, such as smoke detectors, temperature detectors, input/output modules, and each loop can
Connect 10 groups of wireless loops, and one group of wireless loops can connect 20 devices, such as smoke detectors, temperature detectors, input and output modules, etc.
Connect 10 groups of wireless loops, and one group of wireless loops can connect 20 devices, such as smoke detectors, temperature detectors, input and output modules, etc.
Specification
thing | value |
birthplace | China |
Guangdong | |
brand | asenwa |
model | AW-FP200 |
thing | Addressable fire alarm control panel |
Rated input voltage | 85-260VAC 50Hz/60Hz |
spare battery | Two 12V/7Ah lead-acid batteries connected in series |
AC power input fuse | 3.15A/250V 5*20mm glass tube slow-blow fuse |
Battery output fuse | 10A/250V 5*20mm glass tube fuse slow blow |
Auxiliary power | Resettable 24VDC 200mA (maximum) |
FA output | Normal output -12VDC Fire alarm output 24VDC/200mA (maximum) |
fault output | Normal output is 24VDC/200mA (Max), fault output is -12VDC |
Maximum load current per circuit | 24VDC 1A (maximum) |
size | 424*501*127mm |