Plastic smoke detector cover with fire alarm
- $1.00 / >=10 pieces
- 10 pieces
- Hengdun Firefighting Technology Co., Ltd.
- Fujian, China
- Mr
brand: | Hengdun | model: | HDSS16823 |
Key words: | Smoke Detectors | usage: | Smoke detector |
port: | Xiamen | output: | : switch transducer |
Certificate: | :BRE LPCB EN54-7C | strength: | DC10-30V |
payment terms: | L/C,T/T,Western Union | manufacturer: | ex-factory price |
Supply capacity: | 8000 smoke detectors per day | theory: | current sensor |
Material: | Double-sided glass | Packaging Details: | carton smoke detector |
warranty period: | 2 years | place of origin; place of origin: | Fujian China |
Design patent number: | 201130310516.3 |
1. Standalone smoke detector
Power supply: 9v battery (6 sections) made (DC)
Static: < 10 ua
Warning: Current < 35 ma
Acuity: 2.06%/ft +/- 1.3
Alarm indication: red LED flashes
Alarm sound pressure: 85dB/3m or higher
Wireless transmission frequency: 315 MHZ / 433 MHZ (non-linear)
Launch distance: 200 m (empty)
Working temperature: -10℃~+50℃
Relative humidity: below 95% RH
Size: 105*58mm
Executive standard: GB4715-2005.En14604; UL217
2. Independent smoke detector
2. Sensitivity: 0.16 (dimming coefficient m value)
3. Monitoring current: < 15 ua, fire current: < 17 mA
4. Indicator light: three-color light, green is normal, red is fire, yellow is fault
5. Alarm volume: > 80 decibels before (3 meters)
6. Protection area: 40㎡ or refer to the design specification for automatic fire alarm system for specific parameters (GB50116-1998)
7. Ambient temperature: -10°C to +50°C Relative humidity: below 95% (40°C, no condensation)
8. Service life: >10 years
9. Appearance size: diameter 107 mm, height 44 mm
10. Shell material and color: white ABS
11. Weight: 136 grams
12. Installation hole distance: 78mm
1.SOS alarm
The device can send SMS for SOS alarm.
Press the SOS button, the alarm LED lights up and the buzzer starts ringing (default ringing time is 3 minutes). Then the device sends an alarm SMS to the preset main number. Pressing the button again will stop the buzzer and the device will return to its pre-alarm state.
The alarm SMS number (up to 5 groups), the main number (1 group), and the content of the SMS can be set by the user. (Please refer to the "System Settings" below for the detailed setting method.) The default SMS is "Fire Alarm".
2. Smoke alarms
The device's smoke detection is based on optoelectronic technology. When it detects smoke, it makes a call and sends a text message to a preset phone number.
If triggered again within 3 minutes of the first alarm, the device will not issue an alarm signal. And within 3 minutes, if the user presses the SOS button, or arm the device via SMS, the buzzer will stop ringing, and the device can return to detection after 1 minute and 40 seconds.
After sending the alarm SMS, the device will automatically enter the armed state.
3. Reset
Press and hold the SOS button for 5 seconds, (release until the buzzer emits a long sound), the device will return to the factory state. All settings will be restored to default values.
Operation guide
1. Insert the SIM card into the card slot. Make sure your SIM card has enough balance to make calls and send text messages.
2. Connect the power adapter. The LED indicator will be on for about 10 seconds, and the device will start a self-test. If a SIM card is detected, the buzzer will beep twice; if not, it will beep four short beeps. If the indicator light flashes once every two seconds, it means that the main number has not been set; if it keeps flashing fast, it means that the main number is set, but the SIM card is not detected.
3. To make sure all settings are default before use, you can reset them.
4. Set the main number. Only this number can set the smoke alarm.
5. Now you can make other settings and use this device.
6. In the whole working state, the device will check the GSM network. Then the GSM signal is below 20% (not enough to make calls and send text messages) and the Alert LED will keep flashing fast as before. At this time, the position of the device should be replaced until the signal indicator is normal.
7. This device has a power off/restore reminder function. When the external power supply is disconnected, it is powered by the backup battery and sends the SMS "Power Charger Off". The external power supply recovery text message is "Power Charger on".
4. Wire Smoke Detector
main feature:
Power non-polar input
Infrared photoelectric sensor
MCU processing to eliminate false positives
SMT manufacturing process, high stability
Dust-proof, moth-proof, anti-light interference design
Stainless steel shield, anti-RF interference (20V/m-1GHz)
Executive standards: UL268, GB4715, EN54-7
Technical Specifications:
model. | SR-801PC-2/SR-802PC-2/SR-811PC-2 | SR-801PC-4/SR-802PC-4/SR-811PC-4: |
Operating Voltage | DC9~35V | |
Quiescent Current | 55uA | 12mA(NC); 500uA(NO) |
Alarm current | 35mA@DC12V; 60mA@DC24V | 10mA (normally closed); 18mA (normally open) |
Sensitivity | 0.5dB/m(±0.01dB/M) | 0.5dB/m(±0.01dB/M) |
Alarm Output | Remote LED Indicators | relay output |
Install | ceiling mount | ceiling mount |
working environment | -10℃~+50℃(≤95%RH non-condensing) | -10℃~+50℃(≤95%RH non-condensing) |
aspect | 104*49mm (SR-801/SR-802) | 100*48mm (SR-811) |
5. Standalone smoke detector
power supply | 9V DC block battery/PP3 |
Quiescent Current | ≤10µA |
Alarm current | 16 mA |
humidity | 0to95% (40±2°C), no condensation or icing |
Quiescent Current | 8µA |
Operating temperature | -10°C to 50°C |
Alarm decibel | ≥85dB at 10 feet (3 meters) |
test button | Verify that the smoke function is normal alarm |
smoke sensitivity | 0.086 dB/m to 0.140 dB/m |
Low voltage warning | Smoke alarms go off every 40 seconds 30 days (minimum) to indicate Battery needs to be replaced |
6. Standalone smoke detector
1. Easy to install, including mounting hardware
2. 9 volt battery included
3. Test button for any room, convenient to recommend monthly test
4. Low battery signal
5. To protect you, the safety clip does not allow the installation of a smoke alarm without a 9 volt battery installed
6. Ionization chamber for early detection from all directions
7. Loud 85db alarm signal
Power supply: 9vdc | ||
Working current: quiescent current <200uA | ||
Working current: ≤20uA | ||
Buzzer sound level: 85dB at 20 inches | ||
Alarm indication: red LED |
| |
Working temperature: -10℃~+50℃ |
| |
Ambient humidity: ≤95%RH |
| |
Alarm mode: relay on/off |
| |
Size: 107*35mm |
|
7. Standalone photoelectric smoke detector
1) Material: ABS plastic
2) Assembly without wiring, size: Dia.104xH35mm
3) Power supply: 9V lithium battery (including battery)
4) Standby current: 8μA, alarm current: 16mA
5) Ambient temperature: -10°C ~ +50°C
6) Ambient humidity: 0 to 95% (40±2°C)
7) Alarm decibel: greater than 85dB at 10 feet (3 meters)
8) Tamper-resistant locking pin
9) Test button: Verify that the detector functions properly
10) Low Voltage Warning: The device beeps every 40 seconds for 30 days (minimum), indicating that the battery needs to be replaced
11) Smoke sensitivity: according to EN 14604
12) CE, ROHS, EN 14604
13)5 Years Quality Guarantee
8. Standalone Photoelectric Smoke Detector .
1) Material: ABS plastic
2) Assembly without wiring, size: Dia.104xH35mm
3) Power supply: 9V carbon zinc battery/PP3 (including battery)
4) Standby current: 8μA, alarm current: 16mA
5) Ambient temperature: -10°C ~ +50°C
6) Ambient humidity: 0 to 95% (40±2°C)
7) Alarm decibel: greater than 85dB at 10 feet (3 meters)
8) Tamper-resistant locking pin
9) Test button: Verify that the detector functions properly
10) Low Voltage Warning: The device beeps every 40 seconds for 30 days (minimum), indicating that the battery needs to be replaced
11) Smoke sensitivity: according to EN 14604
12) CE, ROHS, EN 14604
13)5 Years Quality Guarantee
9. Independent smoke detector (current and battery backup)
1. Power supply: 12/24VDC/9VDC
2. Working current: quiescent current <5uA,
3. Working current: 20-40mA
4. Alarm temperature: standard 50-70℃
5. Ambient humidity: 10-90%RH
6. Buzzer sound level: 85dB from 10 inches away
10.YT102 Traditional smoke detector, operated by advanced MCU expert algorithm software.
1. Power supply: DC-9V-28V
2. Ambient humidity: ≤95%RH(40℃±2℃)
3.≤60µA @ 24VDC
4.≤30mA@24VDC
5. Buzzer sound level: 85dB in distance 3ms
11.Self-contained battery powered 2-10 year smoke detector
1. Model: JTY-GD-H365 |
2. Power supply: 9V battery (included) |
3. Standby current: less than 10uA |
4. Alarm current: less than 20mA |
5. Sound alarm: greater than 85dB at 3m |
6. Temperature range: 32°F to 104°F (0°C to 40°C) |
7. Humidity range: up to 90% relative humidity (RH) |
8. Sensor: Photoelectric |
9. Dimensions: 4 inches in diameter x 1.28 inches in depth |
10. Dimensions: 4 inches in diameter x 1.28 inches in depth |
11. Weight: 0.2lbs/0.1kg |
12. Interconnect: No |
13. Warranty: 1 year limited |
14. Sign number: ROHS8.807.326 |
15: Battery working time: 3 years or 10 years |
Other types: